Every 1000 hours – Buhler 2425 User Manual

Page 275

Advertising
background image

SECTION 3 - LUBRICATION AND MAINTENANCE

3-51

EVERY 1000 HOURS

OPERATION 50

Change the Engine Inner and Outer Air

Cleaner Elements

2360 and 2425 models illustrated.

The engine air cleaner consists of a large outer

element, smaller safety element, and an exhaust

aspirated precleaner. The precleaner removes

dirt from the air and discharges it through the

exhaust muffler.

IMPORTANT: When servicing the air cleaner,

wear a mask when changing the air filters. Do not

breath in dust.

To access the inner and outer elements, remove

the large wing nut, 1, on the outside of the cover.

Remove the cover, 2, from the cleaner.

Figure 3-72

2

1

Remove the outer element, 1, by removing the

wing nut, 2, and pulling the element from the

canister. Discard the old element.

Figure 3-73

2

1

Remove the inner element, 1, by removing the

wing nut, 2, and pulling the element from the

canister. Discard the old element.

Clean the air cleaner body with a lint-free towel

before installing the element.

Figure 3-74

2

1