SECTION 2 - OPERATION

2-83

If

the

Operator

does

not

press

the

acknowledge/reset button during the pre--alarm

sequence, the EICS will progress to the full

critical alarm stage. The EICS will display a

constant “STOP” message in the upper portion

of the display and the lower portion will display

all symbols related to the rotary select switch.

The audible alarm will become a steady, solid

tone. If the automatic shutdown system is

enabled on the tractor, the engine will shut off

automatically. If the automatic shutdown system

is not enabled, the tractor will continue to run.

See “Automatic Shutdown Conversion” in the

Operator’s manual for information on how to

enable and disable this system. Pressing the

acknowledge/reset button will not clear the

display or audible alarm after the EICS has

reached the critical alarm stage.

ATTENTION: If the tractor electrical system is

not converted to the automatic shut down mode,

the engine will continue to run at a high engine

coolant temperature. Serious engine damage

can result from running the engine in this

condition. It is imperative that the high coolant

temperature condition be corrected and

investigated as soon as possible so as to avoid

serious engine damage.

If the tractor is shut down and then restarted, and

the alarm condition still exists on the tractor (High

Engine Coolant Temperature), the EICS and

module will repeat the alarm and derate

sequence. If the tractor is restarted and the alarm

condition has been corrected, the tractor will

return to normal operation. If the tractor is not shut

down, and the alarm condition is corrected, the

tractor will return to normal operation without

having to shut it off and restart it.

Advertising