SECTION 3 - LUBRICATION AND MAINTENANCE

3-17

EVERY 10 HOURS OR DAILY

2360 and 2425 (N14) Engine

Loosen the compressor pivot bolt located behind

the compressor next to the engine block. Loosen

the adjuster clamp bolt, 1, and adjustment

locknut, 2. Tighten the adjuster bolt, 3, to

increase belt tension. Tighten the adjuster clamp

bolt, 1, locknut, 2, and pivot bolt after the correct

belt tension is obtained. Recheck the belt tension

once all hardware is tightened. Torque the pivot

bolt and adjuster clamp bolt to 79 N⋅m (58 ft. lbs.),

and the locknut to 61 N⋅m (45 ft. lbs.).

IMPORTANT: Do not adjust belt tension to full

value with the adjusting screw. Belt tension can

increase when the locknut is tightened and,

therefore, reduce belt and bearing life.

If the belt requires replacement, the adjustment

should be backed off all the way, and the belt

slipped up around the pulleys. Install the new belt

by reversing the procedure and tension it as

detailed above. Never pry a belt off or on a pulley

as damage to the pulley and belt may result.

NOTE: The air-conditioning compressor

drive belt is supplied by Buhler Versatile.

Contact your Buhler Versatile dealer to

obtain a new belt.