P stc-2002, Deposition controller y – INFICON STC-2002 Thin Film Deposition Controller Operating Manual User Manual
Page 160
p STC-2002
DEPOSITION CONTROLLER
y
SECTION 5.XX
e page 158 of 276 ^
217 IT Event
Final
Thickness
Trigger (from measurement or external)
218
IT
Event
Rate measurement system (from crystal onward) failed
219
IT
Event
Zero Thickness Event Requested / Performed
220
IT
Event
Setpoint Time Triggered Condition
221
IT
Event
Setpoint Thickness Triggered Condition
222
IT
Event
Set Manual Mode Off
223
IT
Event
Set Manual Mode On
224
IT
Event
Metronome Timer Event in Seconds (Once Per Second Event)
225
IT
Event
Metronome Timer Event in Minutes (Once Per Minute Event)
226
IT
Event
Metronome Timer Event in Hours (Once Per Hour Event)
227
IT
Event
Begin Job/Process Event
228
IT
Event
Begin Job/Film Event
229
IT
Event
Begin Job/Deposit Event
230
IT
Event
End Of Job/Deposit Event
231
IT
Event
End Of Job/Film Event
232
IT
Event
End Of Job/Process Event
233
IT
Event
Rate Ramp Trigger (Rate Ramp Starts if Enabled)
234
IT
Event
Gun 1: pocket good
235
IT
Event
Gun 2: pocket good
236
IT
Event
Gun 3: pocket good
237
IT
Event
Gun 4: pocket good
238
IT
Event
Gun 5: pocket good
239
IT
Event
Gun 6: pocket good
240
IT
Event
Gun 7: pocket good
241
IT
Event
Gun 8: pocket good
242
IT
Event
Release Film Hold Event
243
IT
Event
Release Soak Hold Event
244
IT
Event
Trigger Request To Rescan Sensor Map Matrix
245
IT
Event
Channel 1: Thickness Zero
246
IT
Event
Channel 2: Thickness Zero
247
IT
Event
Channel 3: Thickness Zero
248
IT
Event
Channel 4: Thickness Zero
249
IT
Event
Channel 5: Thickness Zero
250
IT
Event
Channel 6: Thickness Zero
251
IT
Event
Channel 7: Thickness Zero
252
IT
Event
Channel 8: Thickness Zero
253
IT
Event
Gun 1: Reset Output Power (only works on non-active sources)
254
IT
Event
Gun 2: Reset Output Power (only works on non-active sources)
255
IT
Event
Gun 3: Reset Output Power (only works on non-active sources)
256
IT
Event
Gun 4: Reset Output Power (only works on non-active sources)
257
IT
Event
Gun 5: Reset Output Power (only works on non-active sources)
258
IT
Event
Gun 6: Reset Output Power (only works on non-active sources)
259
IT
Event
Gun 7: Reset Output Power (only works on non-active sources)
260
IT
Event
Gun 8: Reset Output Power (only works on non-active sources)
261
IT
Event
Channel 1: User Fource Fails Sensor Channel
262
IT
Event
Channel 2: User Fource Fails Sensor Channel
263
IT
Event
Channel 3: User Fource Fails Sensor Channel
264
IT
Event
Channel 4: User Fource Fails Sensor Channel
265
IT
Event
Channel 5: User Fource Fails Sensor Channel
266
IT
Event
Channel 6: User Fource Fails Sensor Channel
267
IT
Event
Channel 7: User Fource Fails Sensor Channel
268
IT
Event
Channel 8: User Fource Fails Sensor Channel
269
IT
Event
Measurement at Rate for 4 Seconds
(event 154 function duplicate)
270
IT
Event
I/O Auxiliary Stop 1
271
IT
Event
I/O Auxiliary Stop 2
272
IT
Event
I/O Auxiliary Stop 3
273
IT
Event
I/O Auxiliary Stop 4
274
IT
Event
Start Coupling (for non-sequencing film starts linkage)
275-299
Available
300 - 399
All
State
1
st
Soft Node To Last Soft Node
400 To 409
ISCAD
Counter
Modulo 100 Counters [10 counters]
Table 5.4: Event And State ID List. [
…continued from previous 3 pages]
Function Index
I INPUT
O OUTPUT
T TRIP
A ARM
D DROP
S SET
C CLEAR
Type Values
B Boolean
V Scalar
M Bitmap
(combined bit
weights)
E Event