DEPOSITION CONTROLLER

y

SECTION 2.XX

e page 35 of 276 ^

disconnects
here

bus board

power supply header

IEC switch/connector

back panel

DC
Header








Pendent:

Also called a hand controller,

may be connected by means of the front panel jack labeled Manual

Control when certain front panel functions need to be duplicated remotely or when intending to utilize the
Manual mode. When not in use, the pendent may be left plugged into the STC-2002 unit or it may be
removed. The pendent does not contain any active electronics nor is it polled to check for its presence.

LCD contrast/bias: The optimal viewing is designed for perpendicular to about 45

° up and about 45° from

perpendicular to either side. Within a few minutes of powering the unit on, there will be some thermal drift
effecting color but this should be relatively unnoticeable. If, however, the unit will be in an environment
having elevated ambient temperatures (above 30

° Celsius), the LCD contrast/bias should be set to low

through menu programming (Main/Executive/System Config

uration

menus).


Graphical Display:
Although no hardware other than the LCD display is associated with this item, it needs
to be setup. Three film parameters need to be programmed: Plot Vert Sc

a

l

e

V

olts,

Plot Hor

i

z Sc

a

l

e

H, Data

Plot Type. The graphical display, as the name implies, displays, in graph form: rate deviation, rate or
power.

Rack Mounting: Rack mounting ears and screws are supplied with the STC-2002 for the purpose of
mounting the unit in a standard rack.

Rubber Feet:
Rubber feet are not supplied with the STC-2002. The anticipated usage of the product is
within a rack. If, however, in the unlikely case where the usage will be on a shelf, table or some other flat
surface, rubber feet should be used to prevent sliding with the possible resultant damage. They should be
of the type that sticks on the bottom of the unit. These can be purchased cheaply at many retail outlets.
The waxed paper is first removed from each foot. The foot is then applied to the bottom of the STC-2002
such that they are placed in each corner an inch from the 2 corner surfaces. Subsequently, if the unit will
be rack mounted, remove the rubber feet.

System Hardware Connections:
Except for the generalized previous descriptions, complete system
hardware setup is beyond the scope of this manual. Consult the manuals for each of the components in the
system. The sum of the manuals is less than the whole:

Be forewarned that the general information

contained herein is meant as an overview of the system only, an overview to describe how the STC-2002
integrates with the other components in the system and some of its' typical usage's. The information