INFICON STC-2002 Thin Film Deposition Controller Operating Manual User Manual

Page 19

Advertising
background image

p STC-2002

DEPOSITION CONTROLLER

y

SECTION 1.XX

e page 17 of 276 ^

I/O Function elements:

[Menu end point: I/O Setup

Menu path: Main/Executive menu/ I/O Setup]

I/O Relay Functions

user I/O program

(8 Form C Relays per card [4 slots available for I or O cards])

I/O Input Functions

user I/O program + PCB jumpers

(8 Inputs per card [4 slots for I or O cards])

I/O Setup

Memory: save/swap, Operate: run/stop

I/O Programming

Edit (Program): IN, NOT, AND, OR, XOR, POS

itive

, NEG

ative

,

OUT, TR

i

P, SET, CL

ea

R, ARM, DR

o

P, (events/states/logical

operators), (softnodes) and (numeric elements).
Arithmetic operators/elements: KON# (to input constants), ADD,
SUB

tract

, MUL

tiply

, DIV

ide

, MOD

ulus

, EQU

als

, GR

ea

T

er than

,

LES

s than

, and SEL

ect

. Editing: ba

c

ksp

ace

, left/right arrows (to move

cursor), del

ete

, undo, ins

ert

/del

ete

line.

(Front Panel LEDs [4 discrete])

I/O programming elements (see table x in section 5xx and Section 2.2)

(User Front Panel Keys [4])

I/O programming elements (see table x in section 5xx and Section 2.2)

Pendent

Keys

(beyond

specified

Manual Mode use: I/O programming elements

[see table xxx in section 5xx ])

Service Menu values:

[Menu end point: Service

Menu path: Main/Service]

(Test Mode Select)

Test Off, Test On [Test Mode won't remain in effect if power is cycled)

(Seq/Non-seq Mode Select)

Seq(uencing Mode Select en)able, Non-seq(uencing Select enabled)

(Memory Contents)

as is (no modification), purged, factory (defaults) [see section x.2.2xx ]

(Reset)

Arm reset, reset armed [Provide a product reset when back panel power
switch is not accessible. Also, use to generate ACCEPT key if not
present (e.g. to end the Test mode when in the Test mode).]


<

<< move the following depenency lists to end of section 2.22? >>

>

[Prerequisite states that must be in effect for the following parameters to be fully functional]

Film Parameter Dependency List:

Material

Density

Not

Applicable

Material

Z-Factor

N.A.

Setpoint Thickness Limit

N.A.

Final Thickness Limit (Trigger)

Service Menu Parameter: Non Seq / Accept

Setpoint Time Limit

N.A.

Soak 1 P

o

w

e

r

level

Value

N.A.

P

o

w

e

r Ramp 1 Time

(to pwr level)

N.A.

P

o

w

e

r Soak 1 Time

(@ pwr level)

N.A.

Soak 2 P

o

w

e

r

level

Value

N.A.

P

o

w

e

r Ramp 2 Time

(to pwr level)

N.A.

P

o

w

e

r Soak 2 Time

(@ pwr level)

N.A.

Soak 3 P

o

w

e

r

level

Value

N.A.

P

o

w

e

r Ramp 3 Time

(to pwr level)

N.A.

Deposit Rate

(requested)

N.A.

Rate Ramp Mode

N.A.

New Dep

osit

Rate

Value

Film Parameter: Rate Ramp Mode = ON

Rate Ramp Time

Duration

Film Parameter: Rate Ramp Mode = ON

Rate Ramp

(Thickn)

Tr

i

g

ge

r

Point

Film Parameter: Rate Ramp Mode = ON

Control Loop –P

roportional term

- N.A.

Control Loop –I

ntegral term

-

N.A.

Control Loop –D

erivative term

- N.A.

Max

Power

Limit

N.A.

Abort Max P

o

w

e

r SW

N.A.

Max Power Dwell

Film Parameter: Abort Max Power SW = ON