p STC-2002

DEPOSITION CONTROLLER

y

SECTION 6.XX

e page 233 of 276 ^

happens, its poll status remains until read by the computer interface. It is then reset and waiting to be set by
that event again.
When triggering an event, no value is required since the action of sending the parameter triggers the event.
The following is a Table showing parameter numbers and their equivalent I/O events:

List of computer pollable event codes:

Parameter# Mnemonic I/O

ID# Description

1

STOP

Any stop event, internal or external.

2

START

Any simple start event, internal or external.

3

STARTG

General start event, either I/O or computer.

4

START1

Select & Start Film 1, generated via I/O,COMM in non-
sequencing option unit, or via sequence logic in sequencing-
capable option unit.

5

START2

Same as START1 except for Film 2.

6

START3

Same as START1 except for Film 3.

7

START4

Same as START1 except for Film 4.

8

START5

Same as START1 except for Film 5.

9

START6

Same as START1 except for Film 6.

10

START7

Same as START1 except for Film 7.

11

START8

Same as START1 except for Film 8.

12

START9

Same as START1 except for Film 9.

13

MANLON

A manual on event triggered, possible ignored.

14

MANLOF

A manual off event, possible ignored.

15

MUPDT

A manual pendant update generated, caused by pendant logic or
computer interface to control manual power when in manual. Ties
into status command G MCTL(3) = 0..3.

16

FTRG

Final thickness trigger event. Caused by measurement logic or
I/O or computer interface.

17

XFAIL

Crystal fail event. Caused by measurement logic or I/O or
computer interface.

18

MLACK

Memory Loss Acknowledge event. Caused at power up by
depressing manual button when prompted, or can be caused
through computer interface.

19

ZERO

Thickness zero event, caused through automatic process flow or
via computer interface, I/O or front panel.

20

SPTIME

Setpoint time event.

21

SPTHIK

Setpoint thickness event.

22

PHANTOM

Obsolete, no longer used.

23

PHANTOM

Obsolete, no longer used.

24

CILK00

Computer event links, can only be caused by an RS232/command
or the I/O logic system. Used to tie the I/O ladder system into the
remote host.

25 CILK01

See

CILK00.

26 CILK02

See

CILK00.

27 CILK03

See

CILK00.

28 CILK04

See

CILK00.

29 CILK05

See

CILK00.

30 CILK06

See

CILK00.

31 CILK07

See

CILK00.

32 CILK08

See

CILK00.

33 CILK09

See

CILK00.

34

BRKWT

Break wait event, caused by I/O system, Front Panel Start or host
computer in systems with sequencing enabled.

35

FLMRE

Film reset event, caused by I/O system, Front Panel Start or host