Set process parameters in the procedure table – MTS Series 793 Application User Manual

Page 166

Advertising
background image

MTS MultiPurpose TestWare®

Set Process Parameters in the Procedure Table

Creating a Practice Test Procedure

166

Note

This Group is done when trigger selection ends Group process activity,
but may leave the fan in a running condition at the end of test. There are
a number of ways to design the procedure to ensure that the fan stops
when the test stops, but to minimize complexity they are not included in
this example.

For more information

For information on how to choose specific Start and Interrupt triggers for
individual processes, see

“About Sequencing Processes”

on page 87.

Set Process Parameters in the Procedure Table

To complete this task, make selections in the parameters pane for each process in
the Procedure and Group tables.

1. Define the first Segment Command process (Ramp to Mean).

A. In the procedure table, click the Segment Command (Ramp to Mean)

process icon.

B. In the Segment Command parameters pane, click the Channels tab.

Move all the channels you want to generate the command on to the
Included list. Move all the others to the Available list.

C. Click the Command tab. Select and type the parameters needed by the

test, as follows:

Segment Shape: Ramp for a Time of 3 Seconds.

Channel: 10kN Actuator

Control Mode: Force

Absolute End Level: 3000 N.

D. Click the General tab and observe the default selections.

Segment Command
(Ramp to Mean)

Advertising