Destination tab output units tab – MTS Series 793 Application User Manual

Page 307

Advertising
background image

High Speed Timed Acquisition Process

MTS MultiPurpose TestWare®

Data Acquisition Process Descriptions

307

Note

If the Time signal is selected, data is generated, not sampled. The Time
signal value always starts at zero.

Destination tab

Output Units tab

Destination Tab

I

TEM

D

ESCRIPTION

Buffer Size

Specifies the maximum number of data elements the buffer will store before data is

written to the disk.

Data Header

Includes a label that describes the data on each buffer that is written to a file.

Destination

Specifies where data is saved:

Specimen data file—the process writes buffers of data to the MPT specimen.dat
file in the Specimen.

User-specified data file—the process writes buffers of data to a separate data file
in the Specimen (yourname.dat).

Discard data—the process will not write data to the Specimen.

User Data File

Specifies the name of the file where data is saved. This lets you create separate data

files in the MPT specimen. This control is enabled only when you have selected

User-specified data file in the Destination list above.

Buffer Type

Specifies the buffer type.

Write First Data Header
Only

Specifies if the data header is written for each buffer or suppressed after the first

header is written. If disabled (unchecked), a data header is written for each buffer.

Note

This feature is not recommended for procedures with multiple data
acquisition processes writing data to the same data file.

Output Units Tab

I

TEM

D

ESCRIPTION

UAS

Specifies the unit assignment set that will be applied to acquired data.

Select Other

Displays other existing unit assignment sets from which you can choose a UAS.

This button is enabled only when you select the Other Unit Assignment Set option.

Edit

Opens the Unit Assignment Set Editor so you can modify a unit assignment set.

Advertising
This manual is related to the following products: