Level crossing acquisition process, About the level crossing acquisition process, Level crossing acquisition process 296 – MTS Series 793 Application User Manual

Page 296

Advertising
background image

MTS MultiPurpose TestWare®

Level Crossing Acquisition Process

Data Acquisition Process Descriptions

296

Level Crossing Acquisition Process

About the Level Crossing Acquisition Process

The Level Crossing Acquisition process records data each time the selected
master signal changes by a specific amount.

When you define a Level Crossing Acquisition process, you must define the
level increment at which data is collected.

Level crossing

acquisition example

Assume you want to collect data every time the displacement changes 2
millimeters. You would select the displacement feedback signal as your master
signal, and set the Level Increment to 2 mm.

Now, data will be recorded when the master signal reaches 2 mm, 4 mm, 6 mm,
and so on.

Note

You should not set the level increment below the level of any signal
noise.

Data Points

Level Increments

Data Points

Data is recorded each time the signal moves by the
specified level increment

Advertising