Set Process Parameters in the Procedure Table
MTS MultiPurpose TestWare®
Creating a Practice Test Procedure
169
4. Define the Peak/Valley Data Acquisition process (Acquire Peak/Valley).
A. In the procedure table, click the Peak/Valley Acquisition (Acquire
Peak/Valley Data) process icon.
B. In the Peak/Valley Acquisition parameters pane, click the Signals tab.
Move all the signals you want to take data on to the Included list.
Typical selections for a test like this might include Time, 10kN
Actuator Force, and 10kN Actuator Displacement.
C. Click the Acquisition tab. Type and select the parameters needed for
the test, as follows:
•
Master Signal: 10kN Actuator Displacement
•
Sensitivity: 3.0 mm
D. Click the Destination tab. Type and select the parameters needed for
the test, as follows:
•
Buffer Size: 16000
•
Data Header: Doc Data
•
Destination: Specimen
•
Buffer Type: Circular
E.
Observe the default settings for the Output Units and General tabs.
Peak/Valley Acquisition
(Acquire Peak/Valley)