Max/Min Acquisition Process

MTS MultiPurpose TestWare®

Data Acquisition Process Descriptions

293

For more information

See

“About Buffers”

on page 272.

See

“About Station Signals”

on page 276.

More About the Max/Min Acquisition Process

The data recorded by the Max/Min Acquisition process is the minimum and
maximum values detected since the process was first activated, no matter how
many times the test is stopped. If the test stops (for any reason) before it has run
to completion, the data recorded will still be the highest and lowest values
detected throughout the entire run portion of the test.

If you want the max/min values for a phase of the test, use a different Max/Min
Acquisition process for each phase. Or, you could put a Max/Min Acquisition
process in a repeated Group process. Design it so the Group process ends every
time a stop occurs, using a Program Event process.

A Group process is set up
to run indefinitely. A large
number in the Execute
Process box causes the
Group process to loop
indefinitely until the
procedure is finished.