MTS MultiPurpose TestWare®

Set Process Parameters in the Procedure Table

Creating a Practice Test Procedure

170

5. Define the Digital Input process (Monitor Continuity).

A. In the procedure table, click the Digital Input Detector (Monitor

Continuity) process icon.

B. In the Digital Input Detector parameters pane, click the Inputs tab.

This process monitors the digital input channel (Continuity Monitor).

C. Move the Continuity Monitor to the Included list and ensure that all

other resources are in the Available list.

D. Click the Input Table tab. For the Digital Input labeled Continuity

Monitor, select the High/Low Option.

E.

Click the Settings tab. Type and select the parameters needed for the
test, as follows:

Trigger Mode: Trigger Once

Process triggers when: Any selected input detects its specific event

Log Message As: Information.

F.

Observe the default settings on the General tab.

Digital Input Detector
(Monitor Continuity)