MTS Series 793 Application User Manual

Page 352

Advertising
background image

MTS MultiPurpose TestWare®

Data Limit Detector Process

Event Process Descriptions

352

7. Click the Settings tab.

8. Under Limit Mode, set the limit mode.

9. Under Process completes when, set when the process ends.

10. Optional—Enable (check) the Log Message As control and select the type

of message you wish to generate.

11. Optional—Select an action.

12. Click the Limit Table tab.

13. Verify and, if needed, edit limit values on this tab.

14. Click the General tab.

15. In the Name box, type a name for this process. (You can also name the

process in the procedure table.)

16. Select the Process Enabled check box. (If this box is cleared, the process

will not run.)

17. Optional—In the Counter Type list, click a counter type.

18. Optional—If you enabled a counter, type a Counter Label.

19. Set the desired Start and Interrupt signals for the process in the procedure

table.

Advertising
This manual is related to the following products: