MTS MultiPurpose TestWare®

Fatigue Process

Data Acquisition Process Descriptions

326

Monitoring tab

Monitoring Tab

I

TEM

D

ESCRIPTION

Time Interval (secs)

Specifies the time interval between data transfers (which occur once every

pass).

Data is acquired from each included signal (the signals checked in the “Signals

tab”). The acquired data is peak-picked and sent to the Rainflow counter.

At

the end of a pass, the acquired damage numbers are stored to the data file and

transmitted to the Fatigue Monitoring application. If the Fatigue Monitoring

application is not running, a warning message is written to the MPT Specimen
Log
.

Note

The Fatigue Monitoring application is started automatically if you click
Reset on the MPT control panel after a new Specimen has been
selected.

Data Transfer Mode

Specifies whether the data is processed once, or processed periodically when a

set number of seconds has elapsed.

Send data once, then terminate—The data will be processed once (useful if

you want the statistics monitored only during part of your command signal),

then the Fatigue process will terminate.

Send data continuously—The data will be processed and sent to the Fatigue

Monitoring application every x seconds until the Fatigue process terminates.

Advertising