Mapping tab

The Mapping tab allows you to specify SBC parameters for each control channel.

File Summary tab

Displays a summary of the lookup-table file selected in the Command tab.

Click View to view and/or edit the lookup-table file in a text viewer.

The summary includes:

The names of each lookup table defined in the lookup-table file.

Lookup and Command units.

The number of data points defined in each lookup table.

Mapping Tab

I

TEM

D

ESCRIPTION

Lookup Table

Use the Lookup Table list to specify the lookup table that will supply the
command for that channel. The names that appear in the Lookup Table list are

defined in the Table(x)=table name heading associated with each lookup table.

A lookup table appears in a channel Lookup Table list if the following is true:

That channel includes a control mode that uses the same units defined in the
lookup table’s Command column.

The station configuration contains at least one signal that uses the same units
defined in the lookup table’s Lookup column.

Note

Click the File Summary tab for a listing of each lookup table defined in the
lookup-table file.

Lookup Signal

Use the Lookup Signal list to define the signal used by the selected lookup table.

This signal’s units must match the signal units defined in the lookup table.

Control Mode

Defines the control mode used for the channel.