Peak/valley acquisition process, About peak/valley process, Peak/valley acquisition process 279 – MTS Series 793 Application User Manual

Page 279

Advertising
background image

Peak/Valley Acquisition Process

MTS MultiPurpose TestWare®

Data Acquisition Process Descriptions

279

Peak/Valley Acquisition Process

About Peak/Valley Process

The Peak/Valley Acquisition process records the output of all selected signals
when the software detects a peak or valley in the master signal you specify.

When you define a Peak/Valley Acquisition process, you must define the master
signal, the sensitivity, the signals you will record data on, the data destination, the
buffer type, and the output units.

Sensitivity

A sensitivity value specifies how much the master signal must change to detect a
peak or valley:

•

Setting the sensitivity too low may cause signal noise to be recognized as
peaks and valleys.

•

Setting the sensitivity too high may cause low amplitude signals to be
missed.

Acquired Data Points

Sensor
Signal

Time

Detected
Peaks

Detected
Valleys

Sensitivity =

Advertising