Acquisition Method:

Level Crossing

The Level Crossing Acquisition Method acquires data each time the selected
master signal changes by a specific amount.

When you define a Level Crossing Acquisition Method, you must select the
master signal and define the level increment at which data is acquired.

Master Signal

Selects a signal that determines when data is acquired.

Note

When you select Time you get timed data acquisition, when you select
any of the feedback signals you get level-crossing data acquisition.

Level Increment

Defines how much the signal must change before acquiring data. Initially a

default level increment is displayed, which for Time is 50 mSec, for Count is

1 segment, and for feedback signals such as Actuator Displacement is a
percentage of the signal’s full scale value. Type the desired level increment and

select appropriate units. The level increment must be greater than zero.