MTS MultiPurpose TestWare®

Set Controller Value Process

Other Process Descriptions

434

3. Set the desired Start and Interrupt signals for the process in the Group or

Procedure table.

4. Click the General tab.

A. In the Name box, type a name for this process. (You can also name the

process in the Procedure table.)

B. Select the Process Enabled check box. (If this box is cleared, the

process will not run.)

C. In the Execute Process box, type the number of times you want the

process to run.

D. Optional—In the Counter Type list, click a counter type.

E.

Optional—If you enabled a counter, type a Counter Label.

5. Click the Calc Variables tab.

A. Select the desired calculation variables in the Available list.

B. Use the arrow keys to move the selected items from the Available list

to the Selected list. These items in the Selected list will appear in the
Values page.

6. Click the Calc Parameters tab.

A. Select the desired calculation parameters in the Available list.

B. Use the arrow keys to move the selected items from the Available list

to the Selected list. These items in the Selected list will appear in the
Values page.

7. Click the Values tab, and define new values for calculation parameters and

variables.

Enter a new calculation parameter or variable value.

To enter a new calculation parameter or variable value—in the Value to
Set
text box, type the new value.

To enter an MPT variable as a new calculation value—right-click in the
Value to Set text box, click Assign Variable, and select an MPT variable.

The text box changes color to indicate that an MPT variable is assigned to
that calculation parameter.