MTS MultiPurpose TestWare®

Procedure Has Been Modified, Run Against the

Working with MPT Specimens

152

This version of procedure “def.000” includes the modifications present when it
was last run against the MPT specimen. A copy of the modified procedure was
automatically saved to the mpp file when the test was last run.

The “modified” flag means MPT noted a difference between the version of the
procedure saved by the operator and the version MPT saved to the mpp file when
the test was run. In this case, even though the modified flag is present, both
versions are identical because the modified version was saved by the operator
after the test was run.

Restore procedure

state to

Since the MPT specimen was last run against the snapshot version of “def.000,”
you can choose the state to which it restores. In this case the saved state is Done,
so selecting the saved state brings the procedure back to its done state, which
include information such as counter values as they were when the test was
complete. Clicking Reset brings the procedure back to its starting point, with
counters set to zero.

The Saved state information is stored in the mps file. If the test had been
inadvertently interrupted and you wish to resume the test at (or close to) the point
of interruption, choose this selection.