Road Surface Output Process

MTS MultiPurpose TestWare®

Command Processes

269

9. Use the File Channel and Station Channel lists to map the drive file

channels to the appropriate station channels. Set the Control Mode and
Channel Units as needed.

10. Optional—Select Enable AIC Compensators.

11. Click the Actions tab.

12. Optional—Map station actions to drive file sequences.

13. Click on the Status tab.

14. Optional—Select Show Status Panel at Run Time if you want the Road

Surface Output Status Panel to display when this process is active.

15. Click the General tab.

16. In the Name box, type a name for this process. (You can also name the

process in the procedure table.)

17. Select the Process Enabled check box. (If this box is cleared, the process

will not run.)

18. In the Execute Process box, type the number of times you want the process

to execute.

19. Optional—In the Counter Type list, click a counter type.

20. Optional—If you enabled a counter, type a Counter Label.

21. Set the desired Start and Interrupt signals for the process.