Model 793.71/72 Time History Output Process
Command Processes
256
Acquisition tab
Note
This tab appears only if you have purchased the data acquisition option
of the Time History Output process (Model 793.72).
Note
If you are executing a Time History Output process that includes data
acquisition, and you hold and resume a test, there will be slight
differences between the digitized response and the response you would
have seen if the test had run without holding.These differences should
not be statistically significant.
Acquisition Tab
I
TEM
D
ESCRIPTION
Number of Channels
Specifies the number of channels on which data is acquired and formatted. The
default number is zero.
Directory
Specifies the directory in which the response file (.rsp) will be saved. With the
Specify File Destination selection, you can specify a path for the response
file. The Use Specimen Directory selection saves the response file in the
specimen directory. The default name of the response file is “new.rsp”—type
the desired file name in place of “new.”
Response File
(file icon)
The process stores digitized response test data in a response file. If the
Directory selection is Specify File Destination, the Response File file icon
will be active. Click the file icon to open the Select response file window. Use
the window to select a current response file, save a new response file, and
specify the path.
Output File Channel
Specifies the output file channel.
Station Signal
Specifies the station signal associated with the selected output file channel.
Channel Descriptor
Specifies a descriptor for the selected output file channel that will be stored in
the files header. The default entry is the station signal name.