Digital Input Detector Process

Event Process Descriptions

354

Design considerations

If the signal is high when the process begins:

The High/Low selection will cause the process to trigger when the signal
becomes low.

The Low/High selection will cause the process to trigger when the signal
becomes low, then transitions to high.

The Either selection will cause the process to trigger when the signal
becomes low.

The Channel Low selection will cause the process to trigger when the
signal becomes low.

The Channel High selection will cause the process to trigger immediately.

If the signal is low when the process begins:

The High/Low selection will cause the process to trigger when the signal
becomes high, then transitions to low.

The Low/High selection will cause the process to trigger when the signal
becomes high.

The Either selection will cause the process to trigger when the signal
becomes high.

The Channel Low selection will cause the process to trigger immediately.

The Channel High selection will cause the process to trigger when the
signal becomes high.

Digital Input Detector Parameter Descriptions

Input Table tab

Inputs tab

Selects the signals that will be monitored by the Digital Input Detector process.
Move signals to the Included list if you want to monitor them with this process.

Input Table Tab

I

TEM

D

ESCRIPTION

Digital Inputs

Displays the input signals being monitored by this process.

Options

Defines the type of signal event the process is looking for.