Numerical Data Window

The Numerical Data window displays the current or past values for all damage
data for one pass. This view is updated with the data of a new pass only when the
last pass is displayed. If you use the pass slider to look at a previous pass, this
view will not change when new pass data is received. You can use the slider
again or click on the pass number field to display the latest pass.

Red or purple numbers in the numerical data boxes indicate that these values are
outside the defined limits. Red denotes “upper limit tripped” and purple denotes
“lower limit tripped.”

Numerical Data Window

I

TEM

D

ESCRIPTION

Prints the current limit settings in a tabular form.

Pass

Selects the pass for which you want to display data.

To show numerical data for a particular pass, type the desired pass number, and

then press return.

Active Process

Specifies the desired process or file.

Status bar

Displays the name, full scale and dimensions of the selected channel.