Important: All segments in a motion block, and the programmable I/O
word, become valid as soon as they are downloaded to the module. The
one exception is a downloaded segment corresponding to the currently
active motion segment. In that case, the active segment must complete its
profile or meet its trigger conditions before the new segment becomes
valid. You must ensure that the programmable controller uses the block
transfer write toggle bit in the status block to accurately load the motion
blocks because the module returns no status bits to indicate the current
programmable I/O configuration or the currently loaded motion segments.

Figure 9.1

Motion Block Word Assignments

50084

Up to
56 words

Motion block control word

Motion segment control word 1

Motion segment control word 2

(MS) Desired position

(LS) Desired position

Local velocity

Local acceleration

Local deceleration

Trigger velocity or (MS) trigger position

(LS) Trigger position

Motion segment control word 1

Motion segment control word 2

(MS) Desired position

(LS) Desired position

Local velocity

Local acceleration

Local deceleration

Trigger velocity or (MS) trigger position

(LS) Trigger position

Motion segment control word 1

Motion segment control word 2

(MS) Desired position

(LS) Desired position

Local velocity

Local acceleration

Local deceleration

Trigger velocity or (MS) trigger position

(LS) Trigger position

Programmable I/O Control Word

1st motion

segment

:

Note: A maximum of 6 motion segments can be specified in one motion

block. In total, the module can hold up to 114 motion segments per axis.

.

.

.

2nd motion

segment

.

.

.

nth motion

segment