Installing the Linear Positioning Module

Chapter 5

5Ć4

3.

Set the current/voltage switch for each control loop as shown in
Figure 5.2.

Figure 5.2

Configuring the Analog Outputs

50044

ON

SLIDE

ON

ROCKER

ON

TOGGLE

TYPES OF SWITCHES

The range selection switches have no

effect when

±

10V is selected.

C2

C1

1

2

OPEN

1

2

1771ĆQB

Chassis

±

100mA

±

50mA

±

20mA

±

10V

LOOP 1

LOOP 2

C2

C1

1

2

OPEN

1

2

C2

C1

1

2

OPEN

1

2

C2

C1

1

2

OPEN

1

2

C2

C1

1

2

OPEN

1

2

C2

C1

1

2

OPEN

1

2

4.

If you have selected a current output, set the current range switch to +100
mA, +50 mA, or +20 mA as shown in Figure 5.2. If your device requires a
range that falls between those provided, select the next higher range and
reduce the range using the analog range word in the parameter block.

ATTENTION: If your switch setting does not provide enough
current, the servo valve may not operate to its full capability. On the
other hand, excessive currents may damage the servo valve.