Installing the Linear Positioning Module

Chapter 5

5Ć11

Figure 5.7

Transducer Connections

Belden 8723 or equivalent (50 ft. max.); Belden 8227, Belden 9207, Belden 1162A or equivalent (200 ft. max.)

Belden 8761 or equivalent (25 ft. max.), Belden 9318 or equivalent (50 ft. max.)

Belden 8723 or equivalent (50 ft. max.)

50030

4

5

LOOP 2

TRANSDUCER

+GATE

-GATE

+INTERR

-INTERR

+5 COMMON

Wiring Arm

Terminals

2

4

6

8

10

LOOP 2

1

3

5

7

9

LOOP 1

+GATE

-GATE

+INTERR

-INTERR

+5 VDC

1

1

Ground the shield

at the I/O chassis end.

Ground the shield

at the I/O chassis end.

Ground the shield at

the I/O chassis end.

Transducer

Supply

(Customer Supplied)

- +

+5 Com

LOOP 1

TRANSDUCER

Connect to

Transducer Head

4

55

1

Power Supply

To connect the transducer power supply, follow these steps:

1.

Connect +5 VDC from your power supply to the +5 VDC terminal (9) on
the module.

2.

Connect + VDC from your power supply to the transducer.