Installing the Linear Positioning Module

Chapter 5

5Ć17

Pull-down resistors or double-throw switches are only required if you wish to
connect two or more QB’s. They are not required to control multiple discrete
inputs on a single module.

Figure 5.10

Using PullĆDown Resistors to Control Multiple QB's

50024

LOOP2

AUTO/MAN

START

STOP

JOG FWD

JOG REV

INPUT 1

INPUT 2

I/P COMMON

14

16

18

20

22

24

26

28

Module A

Wiring Arm

10 to 30 VDC

Jog Forward

Jog Reverse

PullĆDown

Resistors

1000 W 2W

LOOP2

AUTO/MAN

START

STOP

JOG FWD

JOG REV

INPUT1

INPUT 2

I/P COMMON

14

16

18

20

22

24

26

28

Module B

Wiring Arm

PullĆDown

Resistors

1000 W 2W

LOOP2

AUTO/MAN

START

STOP

JOG FWD

JOG REV

INPUT 1

INPUT 2

I/P COMMON

14

16

18

20

22

24

26

28

PullĆDown

Resistors

1000 W 2W

Module C

Wiring Arm

ATTENTION: Failure to follow these procedures can result in
sporadic operation of the discrete inputs.