7ć13, Formatting module data (writes) chapter 7, Inćposition band (words 11 and 40) – Rockwell Automation 1771-QB Linear Pos. User Manual

Page 92

Advertising
background image

Formatting Module Data (WRITES)

Chapter 7

7Ć13

Examples: ZeroĆPosition Past the End of the Transducer

The next two examples show the origin past the fully extended position.

Figure 7.13

ZeroĆPosition Past the End of the Transducer Head

ZeroĆposition = +250.000

Positive Limit = +200.0

Negative Limit = +100.0

Negative

Direction

Neg.

Limit

+100

Origin

0

+250

50017

Pos.

Limit

+200

ZeroĆposition = -250.000

Positive Limit = -100.0

Negative Limit = -200.0

Positive

Direction

Pos.

Limit

-100

Origin

0

-250

50018

Neg.

Limit

-200

InĆPosition Band (words 11 and 40)

The in-position band is the area around an endpoint where the in-position bit
turns on. An endpoint can be the result of a setpoint or motion segment move or
a jog. The axis is in-position if:

the axis feed is complete (i.e., desired velocity is zero)

the following error has closed to within the in-position band

Figure 7.14

InĆPosition Band

50062

Position

InĆPosition band

Endpoint

Advertising