Parameter block appendix c – Rockwell Automation 1771-QB Linear Pos. User Manual

Page 185

Advertising
background image

Parameter Block

Appendix C

CĆ3

Figure C.4

Analog Calibration Constant Words (words 3, 4 and 32, 33)

50027

Analog calibration constant for positive motion:

BCD 99.99 ips or 999.9 mmps max.

Binary 327.67 ips or 3276.7 mmps max.

Analog calibration constant for negative motion:

BCD 99.99 ips or 999.9 mmps max.

Binary 327.67 ips or 3276.7 mmps max.

Note: ips = inches per second

mmps = millimeters per second

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

Figure C.5

Transducer Calibration Constant Words (words 5, 6 and 34, 35)

50028

Transducer calibration constant,

BCD or binary

99.9999 microsec/inch or

9.99999 microsec/mm max

Least significant 4 digits

Most significant digits

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

..

.

..

.
...

0

0

0

0

0

0

0

0

Advertising