SNMP Commands

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC

2+3\new_system_mifs_ARC2_latest\SNMP.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY

Syntax

snmp-server view

view-name

oid-tree

{included | excluded}

no snmp-server view

view-name

[

oid-tree

]

Parameters

• view-name—Specifies the name for the view that is being created or

updated. (Length: 1–30 characters)

•

oid-tree—Specifies the ASN.1 subtree object identifier to be included or

excluded from the view. To identify the subtree, specify a text string

consisting of numbers, such as 1.3.6.2.4, or a word, such as System and,

optionally, a sequence of numbers. Replace a single sub-identifier with the

asterisk (*) wildcard to specify a subtree family; for example 1.3.*.4. This

parameter depends on the MIB being specified.

• included—Specifies that the view type is included.
•

excluded—Specifies that the view type is excluded.

Default Configuration

The following views are created by default:

• Default—Contains all MIBs except for those that configure the SNMP

parameters themselves.

•

DefaultSuper—Contains all MIBs.

Command Mode

Global Configuration mode

User Guidelines

This command can be entered multiple times for the same view.
The command’s logical key is the pair (view-name, oid-tree). Therefore there

cannot be two commands with the same view-name and oid-tree.
The number of views is limited to 64.
Default and DefaultSuper views are reserved for internal software use and

cannot be deleted or modified.