Remote Network Monitoring (RMON) Commands

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC

2+3\new_system_mifs_ARC2_latest\RMON.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY

–

falling —Specifies that if the first sample (after this entry becomes

valid) is less than or equal to falling-threshold, a single falling alarm is

generated.

•

owner

name

—Specifies the name of the person who configured this alarm.

(Valid string)

Default Configuration

The default method type is absolute.
The default startup direction is rising-falling.
If the owner name is not specified, it defaults to an empty string.

Command Mode

Global Configuration mode

Example

The following example configures an alarm with index 1000, MIB object ID

D-Link, sampling interval 360000 seconds (100 hours), rising threshold value

1000000, falling threshold value 1000000, rising threshold event index 10,

falling threshold event index 10, absolute method type and rising-falling

alarm.

console(config)# rmon alarm 1000 1.3.6.1.2.1.2.2.1.10.1 360000

1000000 1000000 10 20

show rmon alarm-table

Use the show rmon alarm-table Privileged EXEC mode command to display a

summary of the alarms table.

Syntax

show rmon alarm-table

Command Mode

Privileged EXEC mode