Preface

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC

2+3\new_system_mifs_ARC2_latest\CLI_Preface_DellPlasma.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY

console (config-oob)#

Through CMC GUI

a

Connect to chassis GUI.

b

Go to I/O Module Overview -> A Gigabit Ethernet -> Setup page.

c

Update the OOB IP parameters.

4 Configure the device and enter the necessary commands to complete the

required tasks.

5 When finished, exit the session with the quit or exit command.

Accessing the CLI from CMC

1 From the CMC console, enter

$ connect switch

connect: acquiring remote port.

Connected to remote port.

Escape character is '^\'.

console#

2 Configure the device and enter the necessary commands to complete the

required tasks.

3 To return to the CMC, enter ctrl/\.

When another user is required to log onto the system, the login command is

entered in the

Privileged EXEC

command mode,. This effectively logs off the

current user and logs on the new user.