Remote Network Monitoring (RMON) Commands

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC

2+3\new_system_mifs_ARC2_latest\RMON.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY

Alarm 1

-------

OID: 1.3.6.1.2.1.2.2.1.10.1

Last sample Value: 878128

Interval: 30

Sample Type: delta

Startup Alarm: rising

Rising Threshold: 8700000

Falling Threshold: 78

Rising Event: 1

Falling Event: 1

Owner: CLI

The following table describes the significant fields shown in the display:

Field

Description

Alarm

Alarm index.

OID

Monitored variable OID.

Last Sample

Value

Value of the statistic during the last sampling period. For

example, if the sample type is delta, this value is the

difference between the samples at the beginning and end of

the period. If the sample type is absolute, this value is the

sampled value at the end of the period.

Interval

Interval in seconds over which the data is sampled and

compared with the rising and falling thresholds.

Sample Type

Method of sampling the variable and calculating the value

compared against the thresholds. If the value is absolute, the

variable value is compared directly with the thresholds at the

end of the sampling interval. If the value is delta, the variable

value at the last sample is subtracted from the current value,

and the difference is compared with the thresholds.

Startup Alarm

Alarm that is sent when this entry is first set. If the first

sample is greater than or equal to the rising threshold, and

startup alarm is equal to rising or rising-falling, then a single

rising alarm is generated. If the first sample is less than or

equal to the falling threshold, and startup alarm is equal

falling or rising-falling, then a single falling alarm is generated.

Advertising