Hypertherm HTA Rev 6.00 Operators Manual User Manual

Page 146

Advertising
background image

132

Operator’s Manual


When a cut loss occurs, the initial backup and forward speed is the one that was used last. To toggle
between the move speeds, press the Change Move Speed softkey in the Pause window. The
corresponding speed is displayed in the Move Speed window.


Move to Pierce
Pressing the Move to Pierce softkey allows the operator to directly move to any pierce point.


Enter the information for the desired pierce point and press ENTER. The cutting device will move
directly to the selected pierce point.


Change Cut Mode
The Change Cut Mode softkey changes the restart mode from Cut to Trial/Test or from Trial/Test to
Cut. This allows the operator to move through the part partially as a Cut and partially as an actual
Cut.

Type “B” configured units will switch between Test Run, Manual and Automatic.


Change Move Speed
Is used to toggle through the four Move Speeds available. The four Move Speeds are the Maximum
Machine Speed, High Jog Speed, Medium Jog Speed and Low Jog Speed from the Speeds setups.


Change Consumable
Takes you to the Change Consumable screen.


On-Path Restart
To restart the cut at the pierce point selected using On-Path Backup, press the START key. The cut
speed and the cut mode are the same as they were prior to when the motion was paused, unless the
values have been edited in the Watch window.

While the Pause Window is displayed, the Manual arrow keys are fully functional to move the cutting
device around. This allows the machine to be moved in any direction (not necessarily along the path)
to inspect the partially cut piece. Once the cutting device is moved off the cut path, a different window
is displayed. The Off-path Pause Window is shown below:

Advertising
This manual is related to the following products: