176

Operator’s Manual

Database Features

Save Data
Pressing the Save Data softkey allows the user to save the current process settings to the Hard
drive creating a custom user database based on the eight process variables selected.

Process Defaults
Pressing the Process Defaults softkey allows the user to reset the current settings to factory
recommend factory defaults based on the eight process variables selected.

Save Database
Pressing the Save Database softkey allows the user to save the current User and Factory
databases to diskette. User files are designated with a .usr file extension and the factory files are
designated with a .fac file extension

Examples of user and factory file names.

Mild Steel-Fineline200-Fineline200.usr
Mild Steel- Fineline200-Fineline200.fac


Load Database
Pressing the load Database softkey allows the user to the factory default database files which are
supplied by Hypertherm as a user files ( .usr ) or factory files ( .fac ) from diskette.

It is recommended that the Database be updated through the control rather than the Power
Supply if the serial communications link is enabled.

Test Preflow
Pressing the Test Preflow softkey performs the Test Preflow Gases feature at the HD4070

®

Power supply.

Test Cutflow
Pressing the Test Cutflow softkey performs the Test Cutflow Gases feature at the HD4070

®

Power supply.


Notes:
-

Please refer to the power supply operators manual for complete information on the operation
and setup of the FineLine Power Supply.

-

The FineLine Power Supply parameters must first be enabled in the password protected
Station Configuration Screen to allow the Cut Chart Information for the FineLine to be
available for use.

-

Serial communications for the FineLine Power supply are established on the user select
communication port. The port must be configured for RS-422 operation.