Hypertherm HTA Rev 6.00 Operators Manual User Manual

Page 175

Advertising
background image

Appendix A: Mariner™ & Voyager II™

161

Material Thickness
The desired material thickness for the selected process.

Focal Length
Specific Focal Length lens that needs to be installed in the laser head for the desired process.

Nozzle
Diameter of the nozzle that needs to be installed for the desired process.

The following are the Cut Process parameters within the database, which are then
available to configure the specific process
.

Set Power
The Set Power parameter allows the user set the power ( watts ) to be used during the cut
process.

Cut Speed
Specifies the Cut Speed for the selected material process.

Kerf
Specifies the amount of kerf (cutter compensation) that will be applied to the current part
program.

Cut Height
The Cut Height setup parameter is used to select the desired cut distance from the plate.

Pierce Height
The Pierce Height setup parameter is used to select the desired Pierce Height. This may be
entered as a multiple factor that is calculated value of the Cut Height or an actual Pierce Height
distance.

Lens Cut Position
Sets the Lens Cut Position distance.

Lens Pierce Position
Sets the Lens Pierce Position distance.

Resonator On Time
During automated power up this allows a specific time for the resonator to power up.

Purge Time
Specifies the time delay from torch ignition until motion is enabled.

Pierce Time
Specifies the time delay from when torch completes lowering until motion is initiated at Creep
Speed. Used to allow the plasma torch to completely pierce the material before moving.

Pulse On Time
When Automatic Pulse Mode is selected for pierce control the user can select Pulse on and off
time to adjust the pulse.

Pulse Off Time
When Automatic Pulse Mode is selected for pierce control the user can select Pulse on and off
time to adjust the pulse.

Advertising
This manual is related to the following products: