Operator’s Manual

Input/Output
Allows current state of selected Input, Outputs or Status information to be displayed during cutting.
This can be especially useful in debugging gas control sequencing problems. To add or delete a
desired Input, Output or Status point to the Input/Output list box, highlight the desired item and +
(add) or (delete) keys on the alpha-numeric keypad.

Position
Allows the position for the selected axis to be displayed. Only two axes may be displayed at the
Upper or Middle locations. The Lower location will allow up to four axes to be displayed.

Following Error
Allows the Following Error to be displayed. Following Error is the distance between the position the
control has calculated and the actual position of the torch. A large Following Error may indicate that
the cut speed selected may be beyond the capability of the cutting system. Only two axes may be
displayed at the Upper or Middle locations. The Lower location will allow up to four axes to be
displayed.

Temperature
Selecting to add the Temperature Widgit to the Watch window will display the current temperature
inside the control in Fahrenheit or Celsius (selected at the Special Setups screen). Note: Specific
control hardware required.

Speedometer
Allows cut speed, maximum machine speed and current machine speed to be graphically displayed
while cutting.

Oxy Fuel Torch Tip
Allows the selected oxy fuel torch tip ( 1- 12 ) consumable life to be graphically displayed while
cutting. This is especially useful in helping to determine when the torch tip should be replaced and
keeping track of torch tip data for statistical process control (SPC).

Plasma Torch Tip
Allows the selected plasma torch tip ( 1- 8 ) consumable life to be graphically displayed while cutting.
This is especially useful in helping to determine when the torch tip should be replaced and keeping
track of torch tip data for statistical process control (SPC).

Plasma Electrode
Allows the selected plasma electrode ( 1- 8 ) consumable life to be graphically displayed while
cutting. This is especially useful in helping to determine when the electrode should be replaced and
keeping track of electrode data for statistical process control (SPC).

Process Data
The Process Data option allows the user to view up to four selected items for a selected cut or
marking process. Process timers and status items for Oxy Fuel, Plasma, Marker, Waterjet and Laser
may be selected. Note: The process data will only be displayed during the current cut process.
Example: Plasma 1 process parameters will only be displayed in the Watch window at the main cut
screen while cutting in Plasma 1 Mode.

Laser Nozzle
Laser Nozzle consumable life to be graphically displayed while cutting. This is especially useful in
helping to determine when the nozzle should be replaced and keeping track of nozzle data for
statistical process control (SPC).

HPR Power Supply
Allows the user to view status for inputs, outputs and gas pressures for the HPR130™ autogas
console. Up to four power supplies may be monitored. This is generally used for diagnostics only.