Section 2: Overview

7

Installation and Setup Features

Selectable axis orientation for compatibility with all cutting machines.

Built in oxy-fuel interface with programmable pre-heat time, ignition, and creep speed.

Built in plasma interface with programmable purge time, ignition time, arc-off delay time, and arc-
transferred feedback.

Built in Laser interface with programmable shutter time, power ramp time and pierce time.

Built in Waterjet interface with programmable abrasive output and pierce time.

Programmable servo gains, speeds, Watch Window, machine parameters, and communication
parameters for flexible application.

Interfaces easily to most optical tracing systems for integrated control.

Complete built-in diagnostics for checkout and test.

Hardware Specifications

10.4” (264 mm) VGA Color DSTN LCD Display or optional Active Matrix TFT display. 15” TFT Touch
Screen on some models.

40Gbyte (or higher) hard disk and 1.44Mbyte Floppy disk drive.

2.4 GHZ (or higher) Celeron

®

Processor is available.


512 Mbytes of RAM.

Up to 64 lines of interface signals for cutting and motion logic (gas control, tracing system, markers,
homing, etc.) depending on I/O configuration.

Industrial grade enclosure and keypad designed to minimize RFI/EMI interference.

Surface mount printed circuit board technology.

Two axes optically isolated ±10VDC drive outputs and incremental encoder inputs which are
expandable to 6 axes of motion. Up to twelve axes of motion and 1024 I/O available with optional
SERCOS Interface™. Optional axes available for dual gantry, dual transverse, contoured bevel
head, two rotate, two tilt angle and eight Sensor™ THC applications..
+5VDC single ended or differential encoder inputs.

Optically isolated serial ports with programmable baud rates to 115 K baud. Communication baud
rates of 230K are obtainable using the communication link software provided with the control.
Optional Network Card for connecting directly to a PC Network.

Universal power input (100-240 VAC; 47-63Hz).

Operating environment: 0 to 50°C (32 to 122°F); 95% relative humidity (non-condensing).

An optional Chiller for Mariner style controls is available.