Hypertherm HTA Rev 6.00 Operators Manual User Manual

Page 52

Advertising
background image

38

Operator’s Manual

I/O Configuration Type “M”, “P” and “V” (Timing Diagram)

Press the Space key to view the timing diagram from Setups.


Ignition Time
(Ignition Output) Specifies the length of time that the ignition output is held on at each ignition point.

Marker On Time
(Time Delay) This parameter allows the operator to insert a time delay, which allows the marker to
prepare for operation prior to the start of Marker motion.

Marker Off Time
(Time Delay) This parameter allows the operator to insert a time delay, which allows the marker to
prepare for operation prior to the end of Marker motion.

Marker Up Time
(Torch Up Output) Specifies the length of time to raise the marker at the beginning and end of each
mark.

Marker Partial Up Time
(Torch Up Output) Specifies the length of time for partial raise of the marker at the beginning and end
of each mark. Note: The Partial Raise parameter must be enabled.

Marker Down Time
(Torch Down Output) Specifies the length of time to lower the marker at the beginning of each
marking cycle.

Set Arc Current
The Set Arc Current feature allows the user to set the arc current at the Plasma Marking supply. This
feature uses the “Set Current BCD” output from the control to activate the BCD inputs at the Plasma
Marking supply. EIA RS-274D part program code G59 Vvalue Fvalue for setting current is supported.

Corner Current Percent
The Corner Current Percent feature allows the operator to select a reduced current setting to be
executed when cutting corners to improve marking quality. This value is a percentage of the Set
Current (above) and is active when the Torch Height Disable Output is on.

Ignition
(Ignition Output Enable) The Ignition Off/On selection allows the operator to use the Ignition Output
when marking if set to On.