Operator’s Manual

Manual THC Mode


While at the main cut screen, when cutting with the Command

®

THC in Manual mode, two new

softkeys will become available to manually raise and lower the torch cut height.

Extend
When pressed during the pierce cycle, this softkey extends the pierce timer until it is stopped
either by a Set-Now or Release softkey press.

Set Now
Pressing the Set Now softkey terminates the pierce cycle and saves the new pierce time. The Set
Now softkey is often used in conjunction with the Extend softkey to modify the preset pierce time.

Release
A Release softkey press will terminate a pierce cycle, but will not modify the original pierce time.
The original pierce time is retained for any remaining pierces.

Diagnostics

The current Command

®

THC Interface and Real Time Revision

Levels will be displayed at the Control Information screen when
enabled.