WORD/VIDEO IN connectors

This BNC-type connector is for input of a word clock

signal (44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz,

192 kHz) or a video reference signal (NTSC/PAL black

burst signal, HDTV Tri-Level signal). Use the switch to

set whether or not to terminate with 75Ω.

/

WORD/VIDEO THRU/WORD OUT connectors

This BNC-type connector is for output of a word clock

signal (thru, 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4

kHz, 192 kHz) or a video reference signal (IN connector

signal thru only).
Use the THRU/WORD OUT switch to set the signal

output.

!

75Ω OFF/ON and THRU/WORD OUT switch

Use this switch to make the following settings.
• Whether or not the WORD/VIDEO IN connector has

a terminator (75Ω)

• The WORD/VIDEO output THRU/OUT setting (OUT

is only for WORD)

@

ETHERNET connector

Use this Ethernet connector to connect to a network

for file transfer and to control this unit from an external

source.

#

GROUND terminal

When using a TASCAM RC-HS20PD remote control

(sold separately), depending on the operating

environment, the color display might flicker or noise

might be heard when monitoring. If this occurs, use

the GROUND terminal. (Please prepare a wire to use

with the GROUND terminal.)

PARALLEL connector

The PARALLEL connector on the rear panel allows

external control of this unit. (TASCAM RC-SS20 can be

connected.) The pin assignments are as follows.

Pin No.

Normal

RC-SS20

PonMode

I/O

1

GND

GND

2

PLAY

FLASH 1

I

3

STOP

FLASH 2

I

4

RECORD

FLASH 3

I

5

SKIP FWD

FLASH 4

I

6

SKIP BWD

FLASH 5

I

7

(Reserved)

STOP

I

8

FADER_START

FADER_START

I

9

(Reserved)

(Reserved)

O

10

TALLY_PAUSE

TALLY_PAUSE

O

11

TALLY_RECORD

RESERVED

O

12

TALLY_STOP

TALLY_STOP

O

13

TALLY_PLAY

TALLY_PLAY

O

14

REMOTE_SELECT,

H or Open

REMOTE_SELECT, L

I

15

PAUSE

FLASH 6

I

16

(Reserved)

FLASH 7

I

17

AUX1, FF

FLASH 8

I

18

AUX2, REW

FLASH 9

I

19

AUX3, MARK

FLASH 10

I

20

(Reserved)

FLASH_PAGE

I

21

(Reserved)

(Reserved)

O

22

TALLY_SD

TALLY_SD*1

O

23

(Reserved)

(Reserved)

O

24

TALLY_CF

TALLY_CF*2

O

25

+5V*3

+5V*3

I: Command input for transport control

Internal circuit, +5V pull-up

Triggers from a low input level of 50 msec or more

O: Command output, for tally output

The internal circuit is open collector (10Ω output

impedance)

Output level low when asserted

20 V dielectric strength, 35 mA maximum current

*1 Assigned to CF indicators when connected RC-SS20
*2 Assigned to CD indicators when connected RC-SS20
*3 +5V: 50 mA maximum supplied current

2−Names and functions of parts