10–internal settings, T/c page, Setup page – Teac HS-2 User Manual

Page 94

Advertising
background image

94

TASCAM HS-2

T/C page

Make settings related to time code on this page.

Set to free run

Set to jam sync (and free once)

NOTE

If the Option SY-2 has not been installed, the display is

shaded and the setting cannot be selected.

STATUS
This shows the time code generator mode of the unit and

the time code frame type of the currently loaded project.
GENERATOR
The top line shows the current time code generator.
The bottom line shows the user bits (

UB

).

Touch the

GENERATOR

item

EDIT

button or the user bits

(

UB

) display area to open the

T/C USER BITS

screen.

When the time code generator is in free run mode, touch

the

RESTART

button to reset the time code of the time

code generator to the start time.
TC IN
The top line shows the time of the input time code and

the frame type. The bottom line shows the user bits (

UB

)

of the input time code.
In

FREE RUN

mode, touch the

CAPTURE

button to capture

the current time code and set it as the time code of the

time code generator.
If the time code generator mode is

FREE ONCE

or

JAM

SYNC

, the capture status (

WAITING

) indicator lights green

when waiting for time code, and it turns off after time

code is captured.

START TIME
When you touch the

GENERATOR

item

RESTART

button,

the time when the time code restarts is shown.
Touch the

START TIME

item

EDIT

button or the

START

TIME

display area to open the

START TIME

screen.

SETUP page

Make settings related to the time code generator on this

page.

STATUS
This area shows the currently loaded project’s time code

frame type.
TC GEN MODE
Use the buttons to set the time code generator mode.

NOTE

If the Option SY-2 has not been installed, the display is

shaded and the setting cannot be selected.

FREE RUN button:

The time code generator runs on its own.

FREE ONCE button (default):

After the input time code is captured once, the unit

starts free run mode.

TIME OF DAY button:

If you conduct any of the following operations, the

time will be captured from the internal clock and

free run mode will start.
• Turn the power on
• Set

TC GEN MODE

to this mode

• Reset the internal clock

JAM SYNC button:

When time code is input, the unit synchronizes to it.

If time code input is interrupted, the unit enters free

run mode.

REGEN button:

The unit synchronizes to the input time code.

REC RUN button:

The time code generator only functions during

recording. At all other times, the time code

generator stops.

10–Internal settings

Advertising