Rs-232c connector, Rs-422 connector (attached to option sy-2 board), 2−names and functions of parts – Teac HS-2 User Manual

Page 16

Advertising
background image

16

TASCAM HS-2

When REMOTE Select (pin 14) is set to high, it can be used

as an ordinary parallel controller. When set to low, flash

start mode is enabled. In addition, depending on the

high/low setting of the Flash Page (pin 20), the key assign-

ments are as follows.

Pin 14

Pin 20

Flash start take

Low

High

1–10

Low

Low

11–20

The following example is of a connection that uses a fader

to start and stop playback of this device.

START

STOP

Pin 1 GND

PARALLEL

Pin 8

FADER START

For information about the assignment of AUX 1–3 (pins

17–19) functions, see “PARALLEL page” on page 96.

NOTE

When controlling this unit with an external device that is

connected to the PARALLEL connector, by simultaneously

asserting the PLAY and RECORD signals while this unit is

stopped, you can start recording immediately. In addition,

by simultaneously asserting the PLAY and RECORD signals

during playback in timeline mode, you can start

overwriting the recording.

RS-232C connector

The RS-232C connector on the rear panel can be

connected to an RS-232C connector on a computer to

allow control of this unit from that computer.
Make settings related to communication on the

RS–232C

page of the

REMOTE SETUP

screen. (See “RS–232C page”

on page 96.)

NOTE

Please contact TASCAM customer support for information

about this unit’s RS-232C command protocol.

RS-422 connector (Attached to Option SY-2

Board)

The Option SY-2 Board is equipped with the RS-422

connector.
You can control this unit remotely by installing the SY-2

Board to this unit and connecting the RS-422 connector

on its rear panel to a controller or editor compatible with

the SONY P2 protocol (RS-422).
Make settings related to operation on the

REMOTE SETUP

screen

RS–422

page. (See “RS–422 page” on page 96.)

NOTE

Please contact TASCAM customer support for information

about this unit’s protocol compatibility.

2−Names and functions of parts

Advertising