Panasonic TH-86EQ2W 85.6" 4K Digital Signage Display User Manual

Page 111

Advertising
background image

111

English

[Crestron Connected] page

Set the information required for connecting the control system of Crestron Electronics, Inc. to the Display, and the

information to monitor/control the Display using the control system of Crestron Electronics, Inc.
Click [Detailed set up

] → [

Crestron Connected].

[Control System]

Configure the setting for the control system required to connect to the Display as a client.

[Use TLS]

Sets the secure communication.

[Disable]:

Performs the unsecured communication.

[Enable]:

Performs the secure communication using TLS

(Transport Layer Security).

[IP Address / Hostname]

Enter the IP address or the host name of the

connection destination.

[IP ID]

Sets the IP ID used to determine the Display on the

network. (A number up to four digits)
Default value: 3

[Room ID]

Sets the Room ID used to determine the Display on

the network. (Up to 32 half-width characters)

[Non Secure Port]

Sets the port number to be used with the unsecured

communication.
Default value: 41794

[Secure Port]

Sets the port number to be used with the secure

communication.
Default value: 41796

[Authentication]

Select the authentication with the connection

destination used with the secure communication.

[Disable]:

Does not perform the connection authentication.

[Enable]:

Performs the connection authentication.

[User Name]

Enter the user name used for the connection

authentication. (Up to 20 half-width characters)

[Password]

Enter the password used for the connection

authentication. (Up to 20 half-width characters)

[Submit]

Updates the [Control System] setting.

Note

When [Use TLS] is set to [Disable], [Authentication] is fixed to [Disable], and [Secure Port] cannot be set.