Information timing – Panasonic TH-86EQ2W 85.6" 4K Digital Signage Display User Manual

Page 85

Advertising
background image

85

English

■

[Serial control]

Selects the RS232-C control terminal.

[SERIAL IN]:

Controls using the SERIAL IN terminal of the

display.

[SLOT]:

Controls via the function board inserted to the

SLOT of this unit.

■

[Display ID]

Set ID number when controlling the Display with

[Controller ID function] and [Serial ID function].

0 to 100

(Standard value: 0)

■

[Controller ID function]

Enables/disables the [Controller ID function].

[Off]:

Disables the [Controller ID function]. (Can be

operated as normal remote control.)

[On]:

Enables the [Controller ID function]. Effective on

switching to [On].

Note

●

To use the [Controller ID function], setting ID numbers

both for the remote control and for the display unit is

required.
For ID number setting for the remote control, see

page 164.

●

About how to reset the settings to defaults, refer to

“Initialization”. (see page 170)

■

[Serial ID function]

Set to control external control with the PC connected to

SERIAL terminal according to the Display’s ID number.

[Off]:

Disables external control by the ID.

[On]:

Enables the external control by the ID.

■

[Serial response (Normal)]

Sets whether to send the response command to normal

commands without ID.

[Off]:

Does not respond. (Including the inquiry command)

[On]:

Responds.

■

[Serial response(ID all)]

Set whether to respond to the command or not, when

serial command of ID number “0” is received.

[Off]:

Does not respond.

[On]:

Responds.

■

[Serial ID group]

When controlling multiple displays simultaneously via

serial communication, those displays are grouped as

one.

A to G

(7 groups)

■

[Serial response(ID group)]

Sets whether to respond to the command or not,

when serial command, which the group is specified, is

received.

[Off]:

Does not respond.

[On]:

Responds.

■

[Serial daisy chain position]

Sets the first and the last terminals of the daisy chain

connection when serial-controlling this unit by the daisy

chain connection via DIGITAL LINK.

[---]:

When controlling this unit alone with serial control,

or connecting at a position other than the first and

last terminals in a daisy chain

[Top]:

When connecting at the first terminal in a daisy

chain

[End]:

When connecting at the last terminal in a daisy

chain

Information timing

Set up the informing manner for no signal or

temperature rising.

RS-232C controls:

Warning or error message sent from the display

automatically.

LAN controls:

Acquire the warning or error message from the

display.

[Information timing] - submenu screen

Information timing

No signal warning
No signal warning timing

Temperature warning

No signal error
No signal error timing

On

5min

On

10min

On

■

[No signal warning]

When set to [On], the display sends out the no signal

warning.

Advertising