Atm pcr, Mgmt class, Input format – Efficient Networks 107-0001-000 User Manual
Page 266: Parameters, Example, Response, Atm pcr -6

Chapter 7: WAN Interface Commands
Page 7-6
Efficient Networks
®
atm pcr
Sets the speed of the ATM link in cells per second.
The default upstream speed is 768 cells/second. Generally, your Network Service
Provider should provide you with your speed value. If your service provider states
your speed value in kilobits per second, enter the value using the
command.
NOTE:
The speed value entered may not be the actual upstream speed attained. When the
command changes the processor clocks, only certain discrete values are allowed.
The speed achieved is the allowed speed value that is equal to or the next lower
value to the value entered (see the example below).
Mgmt Class
Network (R/W)
Input Format
atm pcr [cells/second]
Parameters
Example
The following command requests the current speed.
Response
Typical response when entered with no parameter.
***
When entered with no parameters, the current upstream speed is
displayed.
<cells/second>
a
a
Integer, 294-18867
Upstream speed requested in cells/second.
-> atm pcr 1200
ATM Upstream Rate: 500 Kb/sec or 1179 cells/sec
-> atm pcr
ATM Upstream Rate: 326 Kb/sec or 768 cells/sec