4 at+csq signal quality, At+csq signal quality, At+csq – Siemens MC55 User Manual

Page 193: Obile, Mc55 at command set

Advertising
background image

MC55 AT Command Set

8.4 AT+CSQ

s

m

obile

MC55_ATC_V01.05

Page 193 of 469

2/10/04

Confidential / Released

8.4

AT+CSQ Signal quality

Syntax

Command Description

TA returns received signal strength indication

<rssi>

and channel bit error rate

<ber>

from the ME.

Parameter Description

0

-113 dBm or less

1

-111 dBm

2..30

-109... -53 dBm

31

-51 dBm or greater

99

not known or not detectable

To check the bit error rate there must be a call in progress to obtain realistic values. If no call is set up, there is
no BER to be determined. In this case the indicated value may be 0 or 99, depending on the SIM card.

0..7

as RXQUAL values in the table in GSM 05.08 section 8.2.4.

99

not known or not detectable

Test Command

AT+CSQ=?

Response(s)

+CSQ:

(list of supported

<rssi>

s), (list of supported

<ber>

s)

OK

Exec Command

AT+CSQ

Response(s)

+CSQ:

<rssi>

,

<ber>

OK

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

%

%

%

%

Reference(s)

GSM 07.07

<rssi>

(num)

<ber>

(num)

Advertising