8 at+cfun set phone functionality, At+cfun set phone functionality, At+cfun – Siemens MC55 User Manual

Page 39: Obile

Advertising
background image

MC55 AT Command Set

2.8 AT+CFUN

s

m

obile

MC55_ATC_V01.05

Page 39 of 469

2/10/04

Confidential / Released

2.8

AT+CFUN Set phone functionality

This command serves to control the functionality level of the ME. It can be used to reset the ME, to choose one
of the SLEEP modes or to return to full functionality.
Intended for power saving, SLEEP mode reduces the functionality of the ME to a minimum and thus minimizes
the current consumption. SLEEP mode falls in two categories:
• NON-CYCLIC SLEEP mode

<fun>

=0

• and CYCLIC SLEEP modes, selectable as

<fun>

= 5, 6, 7, 8 or 9.

NON-CYCLIC SLEEP mode permanently blocks the serial interface. The CYCLIC SLEEP mode, however, is a
dynamic process which alternatingly enables and disables the serial interface. The major benefit of all CYCLIC
SLEEP modes is that the serial interface remains accessible and that, in intermittent wake-up periods, characters
can be sent or received without terminating the selected mode. The best choice is using

<fun>

= 5, 6, 7, 8 or 9,

since in these modes MC55 automatically resumes power saving, after you have sent or received a short mes-
sage or made a call.

<fun>

=5 or 6 do not offer this feature to the same extent and are only supported for com-

patibility with earlier releases. In all CYCLIC SLEEP modes, you can enter

<fun>

=1 to permanently wake up

MC55 and take it back to full functionality. Please refer to section

2.8.1

for a summary of all SLEEP modes and

the different ways of waking up the module.
For CYCLIC SLEEP mode (

<fun>

= 5, 6, 7, 8 or 9) both the ME and the application must be configured to use

hardware flow control. This is necessary since the CTS signal is set/reset every time when the ME listens to a
paging message from the base station. This is the way how the module indicates to the application when the
UART is active. For detailed information on the timing of the CTS signal refer to

[2]

. The default setting of hard-

ware flow control is

AT\Q

0 which must be altered to

AT\Q

3. For use after restart you are advised to add it to the

user profile saved with

AT&W

.

If both interfaces ASC0 and ASC1 are connected, hardware flow control must be set in either application.

Syntax

Test Command

AT+CFUN=?

Response(s)

+CFUN:

(list of supported

<fun>

s) , (list of supported

<rst>

s)

OK

Read Command

AT+CFUN?

Response(s)

+CFUN:

<fun>

OK

Write Command

AT+CFUN=

[

<fun>

[,

<rst>

]]

Response(s)

OK

ERROR

+CME ERROR

Advertising