MC55 AT Command Set

4.7 AT+IPR

s

m

obile

MC55_ATC_V01.05

Page 96 of 469

2/10/04

Confidential / Released

4.7

AT+IPR Set fixed local rate

The command

AT+IPR

can be used to set or query the DTE-DCE interface bitrate.

Syntax

Command Description

The test command returns the values of the supported automatically detectable bitrates and the values of the
supported fixed-bitrates.

The read command returns the current bitrate of the interface.

The write command specifies the bitrate to be used for the interface. When you set a fixed-rate, make sure that
both DTE (TE) and DCE (TA) are configured to the same rate. When you select autobauding, the DCE will auto-
matically recognize the bitrate currently used by the DTE.
A selected bitrate takes effect following the issue of any result code associated with this command (e.g. OK).
The setting is stored in the non-volatile memory and will be used whenever the engine is powered up again. How-
ever, in case of autobaud mode (

AT+IPR

=0) the detected DCE bitrate will not saved and, therefore, will resyn-

Test Command

AT+IPR=?

Response(s)

+IPR:

(list of supported auto-detectable

<rate>

s) , (list of supported fixed-only

<rate>

s)

OK

Read Command

AT+IPR?

Response(s)

+IPR:

<rate>

OK

Write Command

AT+IPR=

<rate>

Response(s)

OK

ERROR

+CME ERROR

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

§

§

§

§

Reference(s)